In short
- The H class tells you where the timber may be used: the higher the number, the wetter and harsher the conditions it is treated for.
- H2: dry, indoors, above ground - roof trusses and other covered structural timber.
- H3: outdoors, above ground - decking, pergolas, fascias, fence rails and cladding.
- H4: in the ground - fence posts, deck posts and anything set in soil or concrete. H5 is for fresh water and wet soil, H6 for sea water.
- Seal every cut end, use hot-dip galvanised or stainless steel fixings, and never burn treated offcuts.
Pine is the everyday structural and outdoor timber in South Africa, but untreated pine does not last: insects eat it indoors and fungi rot it outdoors. Pressure treatment forces preservative into the wood, and the hazard class, written as H2, H3, H4 and so on, tells you how harsh a position that piece of timber has been treated for. Buying the wrong class is one of the most expensive small mistakes in building, because the timber looks fine for a few years and then fails where you cannot see it.
What the H classes mean
Treated pine in South Africa is graded by hazard class under SANS 1288. The higher the number, the wetter and harsher the conditions the timber is treated to survive:
| Class | Where it may be used | Typical uses |
|---|---|---|
| H2 | Dry, indoors, above ground (protection against insects) | Roof trusses, rafters, purlins, brandering, indoor framing |
| H3 | Outdoors, above the ground, exposed to weather | Decking, deck joists and bearers, pergolas, fascias, cladding, fence rails and slats |
| H4 | In contact with the ground | Fence posts, deck and pergola posts, garden edging, retaining sleepers |
| H5 | In fresh water or permanently wet soil | Jetty and bridge posts in rivers and dams |
| H6 | In sea water | Marine piles, slipways and harbour work |
A higher class can always do the job of a lower one, but not the other way round. H2 timber used outside, or H3 timber buried in the ground, will fail early.
Which class for which job
Roofs
Timber that stays dry under a roof covering is normally H2, which protects it against wood-boring insects. Wood borer is common in older Western Cape homes, which is why a beetle certificate is often asked for when a house is sold. Remember that the class only covers durability: the sizes, spacing and connections of roof timber are a design matter. A roof truss must be designed for the span, pitch and roof covering - HPM designs and manufactures roof trusses to your plans. Timber that is outside the roof covering, such as exposed rafter ends, fascias and barge boards, sits in the weather and should be H3.
Decks and pergolas
Use H3 for everything above the ground: deck boards, joists, bearers, handrails and pergola beams. Any post that goes into the soil or is cast into a concrete footing must be H4. Many builders avoid burying posts at all and stand them on galvanised or stainless steel post brackets fixed to concrete, which keeps the end grain out of the wet. At a jetty or in a vlei, where posts stand in water or waterlogged soil, ask for H5.
Fences and garden structures
Use at least H4 for fence posts and anything else set in soil. Rails and slats that are clear of the ground can be H3. Set posts in concrete with the top of the concrete sloped away from the post so that water runs off instead of standing against the wood.
Check the mark on the timber
Properly treated structural timber is marked - usually with an ink stamp or an end tag - showing the hazard class and the treater. Look for the H class before the timber leaves the yard, and keep an eye on it when it is delivered: a pack of H2 roof timber and a pack of H3 look almost the same. Colour is not a reliable guide. Some preservatives leave a green tint and creosote leaves timber dark brown, but the shade tells you nothing about the class.
Working with treated timber
- Seal cut ends. Sawing, notching and drilling expose wood that the treatment may not have reached. Brush a suitable timber preservative onto every cut surface before you fix the piece. This matters most on H3 and H4 timber, and most of all on a post end that goes into the ground - keep the factory-treated end down where you can.
- Use the right fixings. The copper in many preservatives attacks plain and zinc-plated steel. Use hot-dip galvanised or stainless steel screws, nails and bolts, and stainless steel close to the sea. See galvanised vs stainless steel fasteners.
- Pre-drill near ends to stop boards splitting, and leave a small gap between deck boards for drainage and movement.
- Protect yourself. Wear gloves, a dust mask and eye protection when sawing, and wash your hands before eating.
- Never burn offcuts. Do not use treated timber in a braai, fireplace or stove; the smoke and ash carry the preservative chemicals. Dispose of offcuts with building rubble.
- Food and water. Do not use treated timber for cutting boards, food containers or anywhere it will be in contact with drinking water.
Sealing and finishing
Treatment stops rot and insects; it does not stop the sun and rain from greying, cracking and cupping the surface. Outdoor timber lasts and looks better with an exterior wood sealer or varnish that is renewed when it starts to look dry. Let newly treated timber dry out before you coat it, apply the finish to all faces where you can reach them, and expect to recoat more often at the coast, where sun and salt are harder on every coating.
Buying timber from HPM
When you ask for a quote, give the hazard class along with the size, length and quantity - for example "38 x 114 mm, 3.6 m, H3, 24 lengths". If you are not sure of the class, tell us what the timber is for and whether it will touch the ground. Timber that is not on the shelf can be sourced on request. Timber lengths are bulky, so they are delivered by our own trucks in the Western Cape or collected in Struisbaai, while screws, bolts, preservatives and sealers can be couriered anywhere in South Africa.
What you need
These links open the matching products in the HPM online store, with live prices (incl. VAT) and stock.
- Decking screws - coated and stainless steel deck screws
- Stainless steel screws and bolts - for timber close to the sea
- Coach screws - for bolting beams and posts
- Timber preservative - for sealing cut ends and treating untreated wood
- Exterior varnish and wood sealer - to protect decks, pergolas and doors from sun and rain
- Wood drill bits - pre-drill near board ends to prevent splitting
- Truss bracing strap - galvanised strap for bracing and tying down
- All fasteners and adhesives
Questions and answers
Which treated pine do I need for fence posts?
Use at least H4 for fence posts and anything else set in soil or concrete. H3 timber is treated for outdoor use above the ground only and will rot early if it is buried.
Can I use H3 timber for a deck?
Yes for the parts above the ground - deck boards, joists and bearers that are clear of the soil. Posts that go into the ground or into concrete footings need H4.
What class is roof truss timber?
Timber that stays dry under a roof is normally H2, which protects it against wood-boring insects. A roof truss must be designed for the span, pitch and roof covering - HPM designs and manufactures roof trusses to your plans.
Is treated pine safe to burn?
No. Never burn treated timber offcuts in a braai, fireplace or stove - the smoke and ash carry the preservative chemicals. Dispose of offcuts with building rubble.
Do I have to seal the cut ends of treated timber?
Yes. Sawing or drilling exposes wood that the treatment may not have reached. Brush a suitable timber preservative onto every cut end, notch and drilled hole before you fix the piece, especially on H3 and H4 timber.
Related guides
Delivery from HPM
Parcels up to 50 kg are delivered by courier anywhere in South Africa, with the rate shown at checkout. Heavy building materials such as cement, bricks, sand, stone and timber are delivered by our own trucks in the Western Cape, and any order can be collected free in Struisbaai.
WhatsApp 076 370 4367 for a quote, call 028 435 6331 or email [email protected].
General guidance only. Products, sites and building rules differ - always follow the product data sheet and your approved plans, and check with your municipality or a registered professional where the work is structural, electrical or needs approval. More short answers: Building Facts & Advice.